{ "description": "BFDProfile represents the settings of the bfd session that can be optionally associated with a BGP session.", "properties": { "apiVersion": { "description": "APIVersion defines the versioned schema of this representation of an object. Servers should convert recognized schemas to the latest internal value, and may reject unrecognized values. More info: https://git.k8s.io/community/contributors/devel/sig-architecture/api-conventions.md#resources", "type": "string" }, "kind": { "description": "Kind is a string value representing the REST resource this object represents. Servers may infer this from the endpoint the client submits requests to. Cannot be updated. In CamelCase. More info: https://git.k8s.io/community/contributors/devel/sig-architecture/api-conventions.md#types-kinds", "type": "string" }, "metadata": { "type": "object" }, "spec": { "description": "BFDProfileSpec defines the desired state of BFDProfile.", "properties": { "detectMultiplier": { "description": "Configures the detection multiplier to determine packet loss. The remote transmission interval will be multiplied by this value to determine the connection loss detection timer.", "format": "int32", "maximum": 255, "minimum": 2, "type": "integer" }, "echoInterval": { "description": "Configures the minimal echo receive transmission interval that this system is capable of handling in milliseconds. Defaults to 50ms", "format": "int32", "maximum": 60000, "minimum": 10, "type": "integer" }, "echoMode": { "description": "Enables or disables the echo transmission mode. This mode is disabled by default, and not supported on multi hops setups.", "type": "boolean" }, "minimumTtl": { "description": "For multi hop sessions only: configure the minimum expected TTL for an incoming BFD control packet.", "format": "int32", "maximum": 254, "minimum": 1, "type": "integer" }, "passiveMode": { "description": "Mark session as passive: a passive session will not attempt to start the connection and will wait for control packets from peer before it begins replying.", "type": "boolean" }, "receiveInterval": { "description": "The minimum interval that this system is capable of receiving control packets in milliseconds. Defaults to 300ms.", "format": "int32", "maximum": 60000, "minimum": 10, "type": "integer" }, "transmitInterval": { "description": "The minimum transmission interval (less jitter) that this system wants to use to send BFD control packets in milliseconds. Defaults to 300ms", "format": "int32", "maximum": 60000, "minimum": 10, "type": "integer" } }, "type": "object", "additionalProperties": false }, "status": { "description": "BFDProfileStatus defines the observed state of BFDProfile.", "type": "object" } }, "type": "object" }